Retrospective assessment of accuracy of nine intraocular lens power calculation formulae in eyes with axial myopia.

Shetty Naren, Shetty Rohit, Nuijts Rudy M M A, Satija Anuj, Roy Abhijit S, Kaweri Luci

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the accuracy of nine conventional and newer-generation formulae in calculating intraocular lens power in eyes with axial myopia.

SETTING

Tertiary eye care center, Bengaluru, India.

DESIGN

Retrospective cross-sectional, comparative study conducted in India.

METHODS

Patients undergoing uneventful phacoemulsification in eyes with axial length >26 mm were included. Preoperative biometry was done using Lenstar LS 900 (Haag-Streit AG, Switzerland). Single eye of patients undergoing bilateral implantation was randomly selected. Optimized lens constants were used to calculate the predicted postoperative refraction of each formula, which was then compared with the actual refractive outcomes to give the prediction errors, following which subgroup analysis was performed. The Kane formula, Barrett universal II, Emmetropia Verifying Optical (EVO) 2.0, Hill Radial Basis Function (Hill RBF) 3.0, Olsen formula, along with Wang Koch-adjusted four formulae, that is, Sanders Retzlaff Kraff/Theoretical (SRK/T), Holladay 1, Haigis, and Hoffer Q formula, were compared for intraocular lens power calculations.

RESULTS

One hundred and sixty-five eyes that fulfilled all the inclusion criteria were studied. Hill RBF 3.0 had the lowest mean and median absolute prediction errors (0.355 and 0.275, respectively) compared to all formulas. In subgroup analysis (26-28, >28-30, and >30 mm), significant difference was seen only in extremely long eyes (>30 mm). The Hill RBF 3.0 formula generated the maximum percentage of eyes with refractive errors within ±0.25, ±0.5, ±0.75, and ±1 D (46%, 76.2%, 89.9%, and 95.8%, respectively).

CONCLUSION

This is the first study evaluating all the formulas exclusively in the myopic eyes. Hill RBF 3 was found to be superior in accuracy to all other formulas.

Для цитирования: Shetty Naren, Shetty Rohit, Nuijts Rudy M M A, Satija Anuj, Roy Abhijit S, Kaweri Luci. Retrospective assessment of accuracy of nine intraocular lens power calculation formulae in eyes with axial myopia.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_1542_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.