DOI 10.1016/j.nefro.2016.06.003
Echocardiographic findings in haemodialysis patients according to their state of hydration.
Аннотация
BACKGROUND
Chronic fluid overload is frequent in hemodialysis patients (P) and it associates with hypertension, left ventricular hypertrophy (LVH) and higher mortality. Moreover, echocardiographic data assessing fluid overload is limited. Our aim was to evaluate the relationship between fluid overload measured by bioimpedance spectroscopy (BIS) and different echocardiographic parameters.
METHODS
Cross-sectional observational study including 76 stable patients. Dry weight was clinically assessed. BIS and echocardiography were performed. Weekly time-averaged fluid overload (TAFO) and relative fluid overload (FO/ECW) were calculated using BIS measurements.
RESULTS
Based on TAFO three groups were defined: A- dehydrated, TAFO <-0.25 L 32 P (42%); B- normohydrated, TAFO between -0.25 and 1.5 l: 26 (34%); C- overhydrated, TAFO>1.5 l: 18 (24%). We found significant correlation between TAFO and left atrial volume index (LAVI) (r: 0.29; p=0.013) but not with FO/ECW (r 0.06; p=0.61). TAFO, but not FO/ECW kept a significant relationship with LAVI (p=0.03) using One-Way ANOVA test and linear regression methods. LVH was present in 73.7% (concentric 63.2%, eccentric in 10.5%). No differences between groups in the presence of LVH or left ventricular mass index were found.
CONCLUSIONS
We found that left atrial volume index determined by echocardiographic Area-length method, but not left ventricle hypertrophy or dimensions of cavities, are related on hydration status based on bioimpedance measured time-averaged fluid overload (TAFO), and not with FO/ECW.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.