MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2024.03.014

Медицинская библиотека · American journal of ophthalmology · 2024

Comparison of Legacy and New No-History IOL Power Calculation Formulas in Postmyopic Laser Vision Correction Eyes.

Anter Abdelrahman M, Bleeker Adam R, Shammas H John, Suraneni Sanjana, Kingrey Brandon, Murphy David A, Leal Sebastian, Ghalibafan Seyyedehfatemeh, Tonk Rahul S, Cooke David L, Riaz Kamran M

СтатьяСравнительное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the refractive accuracy of legacy and new no-history formulas in eyes with previous myopic laser vision correction (M-LVC).

DESIGN

Retrospective cohort study.

METHODS

Setting

Two academic centers Study Population: 576 eyes (400 patients) with previous M-LVC that underwent cataract surgery between 2019-2023. A SS-OCT biometer was used to obtain biometric measurements, including standard (K), posterior (PK), and total keratometry values (TK).

OBSERVATION PROCEDURES: Refractive prediction errors were calculated for 11 no-history formulas: two legacy M-LVC formulas, four new M-LVC formulas using K values only, and five new M-LVC formulas using K with PK or TK.

MAIN OUTCOME MEASURES: Heteroscedastic testing was used to evaluate relative formula performance, and formulas were ranked by root mean square error (RMSE).

RESULTS

New M-LVC formulas performed better than legacy M-LVC formulas. New M-LVC formulas with PK/TK values performed better than versions without PK/TK values. Among new M-LVC formulas with PK/TK values, EVO 2.0-PK was superior to Hoffer QST-PK (P < 0.005). Among new M-LVC formulas using K only, Pearl DGS-K and EVO 2.0-K were both superior to Hoffer QST-K and Barrett True K NH-K formulas (all P < 0.005).

CONCLUSIONS

Surgeons should favor using new no-history post M-LVC formulas over legacy post M-LVC formulas whenever possible. The top-performing M-LVC formulas (EVO 2.0-PK, Pearl DGS-PK, and Barrett True K-TK) utilized posterior corneal power values. Among formulas utilizing K alone, the EVO 2.0-K and Pearl DGS-K performed best.

Для цитирования: Anter Abdelrahman M, Bleeker Adam R, Shammas H John, Suraneni Sanjana, Kingrey Brandon, Murphy David A, Leal Sebastian, Ghalibafan Seyyedehfatemeh, Tonk Rahul S, Cooke David L, Riaz Kamran M. Comparison of Legacy and New No-History IOL Power Calculation Formulas in Postmyopic Laser Vision Correction Eyes.. American journal of ophthalmology. 2024. DOI: 10.1016/j.ajo.2024.03.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.