MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compbiomed.2024.108281

Медицинская библиотека · Computers in biology and medicine · 2024

A new segmentation algorithm for peripapillary atrophy and optic disk from ultra-widefield Photographs1.

Wan Cheng, Fang Jiyi, Li Kunke, Zhang Qing, Zhang Shaochong, Yang Weihua

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

The prevalence of myopia and high myopia is increasing globally, underscoring the growing importance of diagnosing high myopia-related pathologies. While existing image segmentation models, such as U-Net, UNet++, ResU-Net, and TransUNet, have achieved significant success in medical image segmentation, they still face challenges when dealing with ultra-widefield (UWF) fundus images. This study introduces a novel automatic segmentation algorithm for the optic disc and peripapillary atrophy (PPA) based on UWF fundus images, aimed at assisting ophthalmologists in more accurately diagnosing high myopia-related diseases.

METHODS

In this study, we developed a segmentation model leveraging a Transformer-based network structure, complemented by atrous convolution and selective boundary aggregation modules, to elevate the accuracy of segmenting the optic disc and PPA in UWF photography. The atrous convolution module adeptly manages multi-scale features, catering to the variances in target sizes and expanding the deep network's receptive field. Concurrently, the incorporation of the selective boundary aggregation module in the skip connections of the model significantly improves the differentiation of boundary information between segmentation targets. Moreover, the comparison of our proposed algorithm with classical segmentation models like U-Net, UNet++, ResU-Net, and TransUNet highlights its considerable advantages in processing UWF photographs.

RESULTS

The experimental results show that, compared to the other four models, our algorithm demonstrates substantial improvements in segmenting the optic disc and PPA in UWF photographs. In PPA segmentation, our algorithm improves by 0.8% in Dice, 1.8% in sensitivity, and 1.3% in intersection over union (IOU). In optic disc segmentation, our algorithm improves by 0.3% in Dice, 0.6% in precision, and 0.4% in IOU.

CONCLUSION

Our proposed method improves the segmentation accuracy of PPA and optic disks based on UWF photographs, which is valuable for diagnosing high myopia-related diseases in ophthalmology clinics.

Для цитирования: Wan Cheng, Fang Jiyi, Li Kunke, Zhang Qing, Zhang Shaochong, Yang Weihua. A new segmentation algorithm for peripapillary atrophy and optic disk from ultra-widefield Photographs1.. Computers in biology and medicine. 2024. DOI: 10.1016/j.compbiomed.2024.108281.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.