MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2024.102134

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2024

The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human.

Wu Wenjing, Wang Yan, Chen Jingyi, Zhang Fengju

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the biomechanical proteins different between low myopic corneas and moderate to high myopic corneas.

METHODS

A total of 27 myopic corneas were used for the Tandem Mass Tag (TMT) proteomics analysis. Differentially expressed proteins (DEPs) were clustered with fold changes > 1.20 or < 0.83 and p < 0.05. Proteins and Proteins Interactions (PPIs) were conducted to find hub proteins; Uniprot database was to screen proteins with biomechanical functions, and Parallel Reaction Monitoring (PRM) was performed to verify the TMT results. Pearson analysis was used to reveal the correlations between myopic degrees and biomechanical proteins. The Immunofluorescence (IF) staining was used to observe the protein distributions.

RESULTS

In total, 34 DEPs were observed between moderate myopic corneas and low myopic corneas; 103 DEPs were observed between high myopic corneas and low myopic corneas, 20 proteins overlapped. The PPIs analysis showed keratin 2, keratins 10 and PRSS1 were hub proteins. The Uniprot function analysis suggested keratin 2 and keratin 10 exhibited biomechanical functions. The PRM demonstrated keratin 2 and keratin 10 levels were significantly lower in moderate and high myopic corneas, which was consistent with the TMT proteomics results. IF staining also demonstrated keratin 2 and keratin 10 were less distributed in moderate and high myopic corneas than in low myopic corneas.

CONCLUSIONS

The levels of biomechanical proteins keratin 2 and keratin 10 are significantly lower in moderate and high myopic corneas than in low myopic corneas.

Для цитирования: Wu Wenjing, Wang Yan, Chen Jingyi, Zhang Fengju. The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2024. DOI: 10.1016/j.clae.2024.102134.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.