Contact lens & anterior eye : the journal of the British Contact Lens Association · 2024
Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation.
СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Batres Laura, Valdes-Soria Gonzalo, Romaguera María, Carracedo Gonzalo
Аннотация
BACKGROUND: To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation.
METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant.
RESULTS: Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05).
CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.
METHODS: A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant.
RESULTS: Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05).
CONCLUSION: Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.