MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2024.102133

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2024

Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation.

Batres Laura, Valdes-Soria Gonzalo, Romaguera María, Carracedo Gonzalo

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation.

METHODS

A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant.

RESULTS

Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05).

CONCLUSION

Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.

Для цитирования: Batres Laura, Valdes-Soria Gonzalo, Romaguera María, Carracedo Gonzalo. Accommodation response and spherical aberration during 1-Year of orthokeratology lens wear and after discontinuation.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2024. DOI: 10.1016/j.clae.2024.102133.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.