MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20240208-02

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2024

Camellin-Calossi Formula for Intraocular Lens Power Calculation in Patients With Previous Myopic Laser Vision Correction.

Zollet Piero, Romeo Maria Angela, Tripepi Domenico, Vinciguerra Paolo, Vinciguerra Riccardo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction.

METHODS

This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted.

RESULTS

Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D.

CONCLUSIONS

The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction. [J Refract Surg. 2024;40(3):e156-e163.].

Для цитирования: Zollet Piero, Romeo Maria Angela, Tripepi Domenico, Vinciguerra Paolo, Vinciguerra Riccardo. Camellin-Calossi Formula for Intraocular Lens Power Calculation in Patients With Previous Myopic Laser Vision Correction.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2024. DOI: 10.3928/1081597x-20240208-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.