MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/crj.12736

Медицинская библиотека · The clinical respiratory journal · 2017

Endobronchial ultrasound-guided transbronchial needle aspiration with the flexible 19-gauge needle.

Trisolini Rocco, Natali Filippo, Ferrari Marco, Livi Vanina, Paioli Daniela, Romagnoli Micaela, Cancellieri Alessandra

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION AND

OBJECTIVES

Endosonography has become standard of care in the diagnostic work-up of mediastinal lymphadenopathy and peribronchial lung lesions, but its success rate in some specific settings/conditions may be hampered by limited needle flexibility and size. We report on our initial experience with the 19G Flex needle, characterized by larger size and greater flexibility as compared with the currently available cytology needles.

METHODS

Retrospective review of prospectively collected data on the first 13 consecutive patients submitted to endosonography with the 19G Flex needle. Patients were included if they had: (a) suspicion of a histologically complex disease (ie, lymphoma); (b) suspicion of an advanced lung cancer possibly requiring extensive genotyping; (c) a lesion whose sampling with a 22G needle had failed because of lack of visibility when the needle was loaded into the scope.

RESULTS

The 13 patients enrolled had a mean age of 58.15 ± 17 years and a male to female ratio of 8:5. Target lesions (mean size 18.6 ± 6.4 mm) were lymphadenopathies (9 patients), lung lesions (3 patients) and a pleural nodule (1 patient). Histology core/s and a definite diagnosis (adenocarcinoma, 4 cases; lymphoma, 2; mesothelioma, 2, metastases from extrathoracic tumors, 2; non-small-cell lung cancer not otherwise specifiable, 1; small cell carcinoma, 1; sarcoidosis, 1) were obtained in 100% of patients. A single case of self-resolving bleeding was the only complication we observed.

CONCLUSIONS

Preliminary results obtained with the dedicated Flex 19G needle are promising, as sample size/quality is satisfactory and the needle influence on scope flexibility is minimal.

Для цитирования: Trisolini Rocco, Natali Filippo, Ferrari Marco, Livi Vanina, Paioli Daniela, Romagnoli Micaela, Cancellieri Alessandra. Endobronchial ultrasound-guided transbronchial needle aspiration with the flexible 19-gauge needle.. The clinical respiratory journal. 2017. DOI: 10.1111/crj.12736.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.