The international journal of cardiovascular imaging · 2022

Agreement of two vendor-independent strain analysis software platforms in assessing left ventricular global longitudinal strain.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rhee Tae-Min, Kim Hyung-Kwan, Choi You-Jung, Lee Hyun-Jung, Hwang In-Chang, Yoon Yeonyee E, Kim Hack-Lyoung, Park Jun-Bean, Lee Seung-Pyo, Kim Yong-Jin, Cho Goo-Yeong

Аннотация

PURPOSE: The new version of EchoPAC platform was recently developed by General Electronics (GE) to provide 'vendor-independent' full-myocardial-layer left ventricular (LV) global longitudinal strain (LV-GLS). The agreement of the LV-GLS by two vendor-independent software platforms was investigated under diverse clinical situations.

METHODS: Two-dimensional speckle-tracking LV-GLS was separately measured by two software platforms. LV-GLS values were compared as default setting of each software platform (GE full-myocardial-layer [GE-Full], and TomTec endocardial-layer [TomTec-Endo]). Agreements according to various conditions and type of echocardiography vendors were evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICC). Inter-observer reproducibility of each software platform was assessed, and agreements were further evaluated in various subgroups.

RESULTS: One hundred five subjects were initial candidates for the current study (normal LV function without any cardiac pathology [n = 25], hypertrophic cardiomyopathy [n = 40], dilated cardiomyopathy [n = 25], or restrictive cardiomyopathy [n = 15]). After excluding seven subjects with inadequate tracking quality, 98 subjects were finally analyzed. The average LV-GLS was lower in GE-Full than in TomTec-Endo. Agreement between GE-Full and TomTec-Endo was excellent in general; while the greatest bias was observed in the hypertrophic cardiomyopathy group, with TomTec-Endo exhibiting greater LV-GLS values than GE-Full (bias -1.71, limits of agreement -6.02 to 2.59). Both platforms showed excellent inter-observer reproducibility (GE-Full, ICC 0.99; TomTec-Endo, ICC 0.91), and were in good agreements regardless of the echocardiography vendors or subgroups according to age, heart rate, myocardial wall thickness, or LV ejection fraction.

CONCLUSIONS: LV-GLS by GE-Full showed excellent agreement with that by TomTec-Endo under various cardiac conditions.