PURPOSE: To evaluate surgically induced astigmatism as computed by means of either simulated keratometry (KSIM) or total corneal refractive power (TCRP) after temporal incisions.

METHODS

Prospective observational study including 36 right eyes undergoing cataract surgery. Astigmatism was measured preoperatively during the 3-month follow-up period using Pentacam. Surgically induced astigmatism was computed considering anterior corneal surface astigmatism at 3 mm with KSIM and considering both corneal surfaces with TCRP from 1 to 8 mm (TCRP3 for 3 mm). The eyes under study were divided into two balanced groups: LOW with KSIM astigmatism <0.90 D and HIGH with KSIM astigmatism ≥0.90 D. Resulting surgically induced astigmatism values were compared across groups and measuring techniques by means of flattening, steepening, and torque analysis.

RESULTS

Mean surgically induced astigmatism was higher in the HIGH group (0.31 D @ 102°) than in the LOW group (0.04 D @ 16°). The temporal incision resulted in a steepening in the HIGH group of 0.15 D @ 90°, as estimated with KSIM, versus 0.28 D @ 90° with TCRP3, but no significant differences were found for the steepening in the LOW group or for the torque in either group. Differences between KSIM- and TCRP3-based surgically induced astigmatism values were negligible in LOW group.

CONCLUSION

Surgically induced astigmatism was considerably higher in the high-astigmatism group and its value was underestimated with the KSIM approach. Eyes having low astigmatism should not be included for computing the surgically induced astigmatism because steepening would be underestimated.

Для цитирования: Garzón Nuria, Rodríguez-Vallejo Manuel, Carmona David, Calvo-Sanz Jorge A, Poyales Francisco, Palomino Carlos, Zato-Gómez de Liaño Miguel Á, Fernández Joaquín. Comparing surgically induced astigmatism calculated by means of simulated keratometry versus total corneal refractive power.. European journal of ophthalmology. 2018. DOI: 10.1177/1120672118757666.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.