BACKGROUND

This explorative study investigated procedures for the self-assessment of spherocylindrical refractive errors.

METHODS

Eighteen participants with a mean age of 34.0 ± 8.8 years were enrolled. Adjustable Alvarez lenses were mounted in a rotatable ring holder and two procedures were tested for the self-adjustment: (1) rotation of the lens in three meridians: 0°, 60° and 120° and (2) rotation of the optotypes in the same meridians. Starting from maximum positive power, the participants were required to decrease the power of the Alvarez lens until the optotypes (0.0 logMAR) appeared to be clear the first time. Best-corrected visual acuity (BVA) was measured using a psychophysical staircase procedure. Bland-Altmann analysis was carried out in order to calculate the limits of agreement between the self-refraction method and the standard subjective refraction.

RESULTS

Using procedure 1, 77 per cent of the subjects achieved a VA ≥ 0.1 logMAR (6/7.5) and the same was true for 88 per cent of the subjects using procedure 2. Using procedure 1, a significantly worse BVA was found, when compared to subjective refraction (ΔVA = -0.15 logMAR, F3,140  = 7.11, p = 0.046, median test). Analysis of variance (ANOVA) analysis showed a significant influence of the refraction method on the oblique astigmatism component J45 but not for the spherical equivalent M and the straight astigmatism component J0 (M: F3,140  = 0.532, p = 0.661; J0 : F3,140  = 0.056, p = 0.983; J45 : F3,140  = 13.97, p < 0.001; ANOVA). The limits of agreement for the spherical equivalent error M were ± 1.10 D and ± 1.20 D and for the astigmatic components J0 ± 0.78 D and ± 0.59 D and for J45 ± 0.62 D and ± 0.54 D, for procedure 1 and procedure 2, respectively.

CONCLUSIONS

Fixed adjustable Alvarez lenses and rotatable stimuli can provide a fast and precise self-assessment method to measure the spherocylindrical error of the eye.

Для цитирования: Leube Alexander, Kraft Caroline, Ohlendorf Arne, Wahl Siegfried. Self-assessment of refractive errors using a simple optical approach.. Clinical & experimental optometry. 2018. DOI: 10.1111/cxo.12650.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.