DOI 10.1016/j.jcrs.2017.06.040

Медицинская библиотека · Journal of cataract and refractive surgery · 2017

Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation.

Savini Giacomo, Næser Kristian, Schiano-Lomoriello Domenico, Ducoli Pietro

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare keratometric astigmatism (KA) and different modalities of measuring total corneal astigmatism (TCA) for toric intraocular lens (IOL) calculation and optimize corneal measurements to eliminate the residual refractive astigmatism.

SETTING

G.B. Bietti Foundation IRCCS, Rome, Italy.

DESIGN

Prospective case series.

METHODS

Patients who had a toric IOL were enrolled. Preoperatively, a Scheimpflug camera (Pentacam HR) was used to measure TCA through ray tracing. Different combinations of measurements at a 3.0 mm diameter, centered on the pupil or the corneal vertex and performed along a ring or within it, were compared. Keratometric astigmatism was measured using the same Scheimpflug camera and a corneal topographer (Keratron). Astigmatism was analyzed with Næser's polar value method. The optimized preoperative corneal astigmatism was back-calculated from the postoperative refractive astigmatism.

RESULTS

The study comprised 62 patients (64 eyes). With both devices, KA produced an overcorrection of with-the-rule (WTR) astigmatism by 0.6 diopter (D) and an undercorrection of against-the-rule (ATR) astigmatism by 0.3 D. The lowest meridional error in refractive astigmatism was achieved by the TCA pupil/zone measurement in WTR eyes (0.27 D overcorrection) and the TCA apex/zone measurement in ATR eyes (0.07 D undercorrection). In the whole sample, no measurement allowed more than 43.75% of eyes to yield an absolute error in astigmatism magnitude lower than 0.5 D. Optimized astigmatism values increased the percentage of eyes with this error up to 57.81%, with no difference compared with the Barrett calculator and the Abulafia-Koch calculator.

CONCLUSION

Compared with KA, TCA improved calculations for toric IOLs; however, optimization of corneal astigmatism measurements led to more accurate results.

Для цитирования: Savini Giacomo, Næser Kristian, Schiano-Lomoriello Domenico, Ducoli Pietro. Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation.. Journal of cataract and refractive surgery. 2017. DOI: 10.1016/j.jcrs.2017.06.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.