MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20170721-06

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2017

Pupil Dynamics Induced by Light Reflex After Posterior Chamber Phakic Intraocular Lens Implantation.

Totsuka Kazuko, Ishikawa Hitoshi, Kamiya Kazutaka, Shoji Nobuyuki, Shimizu Kimiya

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the light reflex of the pupil after Implantable Collamer Lens (ICL) (KS-aquaPORT; STAAR Surgical, Nidau, Switzerland) implantation to determine whether the ICL implantation might affect the pupil dynamics.

METHODS

This study examined 28 eyes of 28 consecutive patients who underwent implantation of the posterior phakic ICL for the correction of myopia and astigmatism. Patient age at the time of surgery was 31.1 ± 6.8 years (range: 25 to 42 years). Preoperative refraction was -7.38 ± 2.26 diopters (D) (range: -3.25 to -11.80 D). Light reflex was evaluated using the infrared pupillometer Iriscorder C7364 (Hamamatsu Photonics, Hamamatsu, Japan). Measured parameters included pupil diameter (D1), constriction ratio, maximum constriction velocity, maximum dilation velocity, and the time required to recover 63% of the pupil diameter (T5). At 6 months postoperatively, the authors also investigated the relationship with the amount of vault using the Pentacam (Oculus Optikgeräte, Wetzlar, Germany). Evaluations with the instrument were performed before and at 1, 3, and 6 months after surgery.

RESULTS

There was no significant association found between any of the parameters (analysis of variance, D1: P = .99, constriction ratio: P = .59, maximum constriction velocity: P = .87, maximum dilation velocity: P = .13, T5: P =.57). The vault of the ICL at 6 months postoperatively was 382.1 ± 176.5 μm. There were no significant associations between the maximum constriction velocity, maximum dilation velocity, and amount of vaulting (Spearman correlation coefficient maximum constriction velocity: r = 0.07, P = .71, maximum dilation velocity: r = 0.26, P = .28).

CONCLUSIONS

The light reflex of the pupillary dynamics continued to be maintained at 6 months after ICL implantation. Current findings also verified that ICL implantation had little influence on the postoperative function of the iris. [J Refract Surg. 2017;33(10):704-707.].

Для цитирования: Totsuka Kazuko, Ishikawa Hitoshi, Kamiya Kazutaka, Shoji Nobuyuki, Shimizu Kimiya. Pupil Dynamics Induced by Light Reflex After Posterior Chamber Phakic Intraocular Lens Implantation.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2017. DOI: 10.3928/1081597x-20170721-06.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.