MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/ejo.5001028

Медицинская библиотека · European journal of ophthalmology · 2018

Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

García-Bella Javier, Martínez de la Casa José M, Talavero González Paula, Fernández-Vigo José I, Valcarce Rial Laura, García-Feijóo Julián

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT).

METHODS

This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD).

RESULTS

The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants.

CONCLUSIONS

The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

Для цитирования: García-Bella Javier, Martínez de la Casa José M, Talavero González Paula, Fernández-Vigo José I, Valcarce Rial Laura, García-Feijóo Julián. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.. European journal of ophthalmology. 2018. DOI: 10.5301/ejo.5001028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.