A multi-centre North Italian prospective survey on some quality parameters in lower gastrointestinal endoscopy.

Fasoli R, Repaci G, Comin U, Minoli G, Italian Association of Hospital Gastroenterologists

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: To record prospectively, in a multi-centre survey, the adherence to some quality parameters of lower digestive endoscopy in everyday practice, focusing in particular on sedation and monitoring; choice of extension of endoscopic examination by the operator and relative performance in intubation of the caecum; behaviour, in some particular clinical circumstances, such as fresh haematochezia, screening and surveillance situations, functional symptoms, management of polyps.

PATIENTS AND

METHODS

Twenty-five centres located in Lombardia, Italy took part in the study; the duration of the survey was 2 weeks. 1,406 consecutive cases were recorded.

RESULTS

The main indications to colonoscopy were fresh haematochezia (21%). abdominal pain (11.7%) and surveillance after surgery for tumours or endoscopic polyp removal (24.3%). Screening examinations accounted for 7.1% of all examinations. Conscious sedation was administered in 63.9% of patients; pulse oxymetry and cardiac frequency monitoring was used in 44.2% of cases. Total colonoscopy was planned in 84.2% of cases; the actual rate of intubation of the caecum in the cases submitted to the procedure was 84.1%. Normal results were obtained in 24.3%. In 24.3% of patients, one or more polyps were identified; 84.2% of these were removed during the first examination. Four complications (accounting for 0.28% of cases) were recorded, all after polypectomy and all successfully treated conservetively.

CONCLUSIONS

The present study has shown that some attitudes in lower digestive endoscopy are sub-optimal: in particular, screening examinations are still infrequent; conscious sedation and monitoring have probably been used too rarely; intubation of the caecum was achieved in <90% of cases; the endoscopic removal of many polyps has been delayed for unexplained reasons. On the other hand, timing of surveillance after surgery for tumours or endoscopic removal of polyps has, overall, been adequate; the rate of normal examinations and the rate of complications have been satisfactorily low.

Для цитирования: Fasoli R, Repaci G, Comin U, Minoli G, Italian Association of Hospital Gastroenterologists. A multi-centre North Italian prospective survey on some quality parameters in lower gastrointestinal endoscopy.. Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver. 2002. DOI: 10.1016/s1590-8658(02)80252-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.