MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11548-018-01909-7

Медицинская библиотека · International journal of computer assisted radiology and surgery · 2019

A computer-assisted system for handheld whole-breast ultrasonography.

Šroubek Filip, Bartoš Michal, Schier Jan, Bílková Zuzana, Zitová Barbara, Vydra Jan, Macová Iva, Daneš Jan, Lambert Lukáš

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Breast ultrasonography (US) presents an alternative to mammography in young asymptomatic individuals and a complementary examination in screening of women with dense breasts. Handheld US is the standard-of-care, yet when used in whole-breast examination, no effort has been devoted to monitoring breast coverage and missed regions, which is the purpose of this study.

METHODS

We introduce a computer-aided system assisting radiologists and US technologists in covering the whole breast with minimum alteration to the standard workflow. The proposed system comprises a standard US device, proprietary electromagnetic 3D tracking technology and software that combines US visual and tracking data to estimate a probe trajectory, total time spent in different breast segments, and a map of missed regions. A case study, which involved four radiologists (two junior and two senior) performing whole-breast ultrasound in 75 asymptomatic patients, was conducted to test the importance and relevance of the system.

RESULTS

The mean process time per breast was [Formula: see text], with no statistically significant difference between the left and the right sides, and slightly longer examination time of junior radiologists. The process time density shows that central parts of the breast have better coverage compared to the periphery. Within the central part, missed regions of minimum detectable size of [Formula: see text] occur in [Formula: see text] of examinations, and non-negligible [Formula: see text] regions occur in [Formula: see text] of cases.

CONCLUSION

The results of the case study indicate that missed regions are present in handheld whole-breast US, which renders the proposed system for tracking the probe position during examination a valuable tool for monitoring coverage.

Для цитирования: Šroubek Filip, Bartoš Michal, Schier Jan, Bílková Zuzana, Zitová Barbara, Vydra Jan, Macová Iva, Daneš Jan, Lambert Lukáš. A computer-assisted system for handheld whole-breast ultrasonography.. International journal of computer assisted radiology and surgery. 2019. DOI: 10.1007/s11548-018-01909-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.