OBJECTIVE

To evaluate the interpretive performance and inter-observer agreement on digital mammographs among radiologists and to investigate whether radiologist characteristics affect performance and agreement.

MATERIALS AND

METHODS

The test sets consisted of full-field digital mammograms and contained 12 cancer cases among 1000 total cases. Twelve radiologists independently interpreted all mammograms. Performance indicators included the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false positive rate (FPR), and area under the receiver operating characteristic curve (AUC). Inter-radiologist agreement was measured. The reporting radiologist characteristics included number of years of experience interpreting mammography, fellowship training in breast imaging, and annual volume of mammography interpretation.

RESULTS

The mean and range of interpretive performance were as follows: recall rate, 7.5% (3.3-10.2%); CDR, 10.6 (8.0-12.0 per 1000 examinations); PPV, 15.9% (8.8-33.3%); sensitivity, 88.2% (66.7-100%); specificity, 93.5% (90.6-97.8%); FPR, 6.5% (2.2-9.4%); and AUC, 0.93 (0.82-0.99). Radiologists who annually interpreted more than 3000 screening mammograms tended to exhibit higher CDRs and sensitivities than those who interpreted fewer than 3000 mammograms (p = 0.064). The inter-radiologist agreement showed a percent agreement of 77.2-88.8% and a kappa value of 0.27-0.34. Radiologist characteristics did not affect agreement.

CONCLUSION

The interpretative performance of the radiologists fulfilled the mammography screening goal of the American College of Radiology, although there was inter-observer variability. Radiologists who interpreted more than 3000 screening mammograms annually tended to perform better than radiologists who did not.

Для цитирования: Kim Sung Hun, Lee Eun Hye, Jun Jae Kwan, Kim You Me, Chang Yun Woo, Lee Jin Hwa, Kim Hye Won, Choi Eun Jung, Alliance for Breast Cancer Screening in Korea (ABCS-K). Interpretive Performance and Inter-Observer Agreement on Digital Mammography Test Sets.. Korean journal of radiology. 2019. DOI: 10.3348/kjr.2018.0193.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.