MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-018-1402-9

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018

The influence of anthropometric and basic circulatory variables on count rate in cadmium-zinc-telluride SPECT gated radionuclide angiography.

Rydberg Julie, Andersen Jannick, Haarmark Christian, Zerahn Bo

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To determine the influence of weight, height, gender, age, heart rate, and blood pressure on count rate in cadmium-zinc-telluride single-photon emission computed tomography (CZT SPECT) gated radionuclide angiography.

METHOD: A total of 1,065 eligible patients referred for routine assessment of left ventricular ejection fraction were registered from August 2015 to November 2016. Data were recorded on heart rate, systolic and diastolic blood pressure, age, gender, height, weight, and count rate. All radionuclide angiographies were performed on a dedicated cardiac CZT SPECT camera, GE Discovery 530c. A dose of 550 MBq 99mTc-labeled human serum albumin was administered intravenously to each patient.

RESULTS

Count rate varied from 1.2 to 8.9 counts per second. All test variables were significantly associated with count rate. From the preliminary analysis, weight appeared as the main contributing factor for explaining the variations in count rate with and R2 of 0.68. A model consisting of weight, height, gender, and age explains 75% of the variance in count rate.

CONCLUSION

Patient height, weight, gender, and age have significant impact on count rate when performing CZT radionuclide angiography and may subsequently be used for individualized planning of tracer dosage.

Для цитирования: Rydberg Julie, Andersen Jannick, Haarmark Christian, Zerahn Bo. The influence of anthropometric and basic circulatory variables on count rate in cadmium-zinc-telluride SPECT gated radionuclide angiography.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2018. DOI: 10.1007/s12350-018-1402-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.