Automated and Clinical Breast Imaging Reporting and Data System Density Measures Predict Risk for Screen-Detected and Interval Cancers: A Case-Control Study.

Kerlikowske Karla, Scott Christopher G, Mahmoudzadeh Amir P, Ma Lin, Winham Stacey, Jensen Matthew R, Wu Fang Fang, Malkov Serghei, Pankratz V Shane, Cummings Steven R, Shepherd John A, Brandt Kathleen R, Miglioretti Diana L, Vachon Celine M

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead.

OBJECTIVE

To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures.

DESIGN

Case-control.

SETTING

San Francisco Mammography Registry and Mayo Clinic.

PARTICIPANTS

1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants.

MEASUREMENTS: Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity.

RESULTS

Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively.

LIMITATION: Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method.

CONCLUSION

Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density.

PRIMARY FUNDING SOURCE: National Cancer Institute.

Для цитирования: Kerlikowske Karla, Scott Christopher G, Mahmoudzadeh Amir P, Ma Lin, Winham Stacey, Jensen Matthew R, Wu Fang Fang, Malkov Serghei, Pankratz V Shane, Cummings Steven R, Shepherd John A, Brandt Kathleen R, Miglioretti Diana L, Vachon Celine M. Automated and Clinical Breast Imaging Reporting and Data System Density Measures Predict Risk for Screen-Detected and Interval Cancers: A Case-Control Study.. Annals of internal medicine. 2018. DOI: 10.7326/m17-3008.