MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2017.12.028

Медицинская библиотека · Academic radiology · 2018

Communication Practices of Mammography Facilities and Timely Follow-up of a Screening Mammogram with a BI-RADS 0 Assessment.

Schapira Marilyn M, Barlow William E, Conant Emily F, Sprague Brian L, Tosteson Anna N A, Haas Jennifer S, Onega Tracy, Beaber Elisabeth F, Goodrich Martha, McCarthy Anne Marie, Herschorn Sally D, Skinner Celette Sugg, Harrington Tory O, Geller Berta

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

The objective of this study was to evaluate the association of communication practices with timely follow-up of screening mammograms read as Breast Imaging Reporting and Data Systems (BI-RADS) 0 in the Population-based Research Optimizing Screening through Personalized Regimens (PROSPR) consortium.

MATERIALS AND

METHODS

A radiology facility survey was conducted in 2015 with responses linked to screening mammograms obtained in 2011-2014. We considered timely follow-up to be within 15 days of the screening mammogram. Generalized estimating equation models were used to evaluate the association between modes of communication with patients and providers and timely follow-up, adjusting for PROSPR site, patient age, and race and ethnicity.

RESULTS

The analysis included 34,680 mammography examinations with a BI-RADS 0 assessment among 28 facilities. Across facilities, 85.6% of examinations had a follow-up within 15 days. Patients in a facility where routine practice was to contact the patient by phone if follow-up imaging was recommended were more likely to have timely follow-up (odds ratio [OR] 4.63, 95% confidence interval [CI] 2.76-7.76), whereas standard use of mail was associated with reduced timely follow-up (OR 0.47, 95% CI 0.30-0.75). Facilities that had standard use of electronic medical records to report the need for follow-up imaging to a provider had less timely follow-up (OR 0.56, 95% CI 0.35-0.90). Facilities that routinely contacted patients by mail if they missed a follow-up imaging visit were more likely to have timely follow-up (OR 1.65, 95% CI 1.02-2.69).

CONCLUSIONS

Our findings support the value of telephone communication to patients in relation to timely follow-up. Future research is needed to evaluate the role of communication in completing the breast cancer screening episode.

Для цитирования: Schapira Marilyn M, Barlow William E, Conant Emily F, Sprague Brian L, Tosteson Anna N A, Haas Jennifer S, Onega Tracy, Beaber Elisabeth F, Goodrich Martha, McCarthy Anne Marie, Herschorn Sally D, Skinner Celette Sugg, Harrington Tory O, Geller Berta. Communication Practices of Mammography Facilities and Timely Follow-up of a Screening Mammogram with a BI-RADS 0 Assessment.. Academic radiology. 2018. DOI: 10.1016/j.acra.2017.12.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.