MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2021.01.012

Медицинская библиотека · Journal of cardiology · 2021

The clinical value of the apex beat as a marker of left atrial enlargement.

Muro Takashi, Abe Yukio, Takemoto Tomoyuki, Inanami Hitoshi, Nakai Takeo, Okada Yukikatsu

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The palpation of the apex beat, one of the most fundamental physical examinations, provides a clue to left ventricular (LV) dilatation and hypertrophy; however, its relation to left atrial (LA) volume has rarely been investigated.

METHODS

The clinical value of the apex beat, especially in relation to LA volume was studied in 138 consecutive patients. Patients were examined in the supine position for a palpable apex beat. When an apex beat was felt, the apex beat distance, defined as the distance from the mid-clavicular line to the lateral border of the apex beat, was measured. The LA and LV geometry were assessed using echocardiography.

RESULTS

Of the 138 patients, an apex beat was palpable in 52 (38%) patients and the apex distance of these 52 patients ranged from -2 to 8 cm. The parameters of LV dilatation or hypertrophy were significant according to univariate but not to multivariate analysis. Only LA volume index was significant both for the palpability of the apex beat (p=0.0042) and the apex distance (p=0.0017) by multivariate analysis. The best cut-off point for the apex distance was -1 cm for LA enlargement (sensitivity 61%, specificity 92%, p<0.0001).

CONCLUSIONS

The LA volume is the most significant factor for the palpability and leftward deviation of the apex beat. Palpation of the apex beat is a crucial diagnostic tool for the detection of not only LV dilatation or hypertrophy but also of LA enlargement.

Для цитирования: Muro Takashi, Abe Yukio, Takemoto Tomoyuki, Inanami Hitoshi, Nakai Takeo, Okada Yukikatsu. The clinical value of the apex beat as a marker of left atrial enlargement.. Journal of cardiology. 2021. DOI: 10.1016/j.jjcc.2021.01.012.