MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3978/j.issn.2072-1439.2016.01.05

Медицинская библиотека · Journal of thoracic disease · 2016

Bronchodilator response in adults with bronchiectasis: correlation with clinical parameters and prognostic implications.

Guan Wei-Jie, Gao Yong-Hua, Xu Gang, Li Hui-Min, Yuan Jing-Jing, Zheng Jin-Ping, Chen Rong-Chang, Zhong Nan-Shan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Bronchial dilation testing is an important tool to assess airway reversibility in adults with bronchiectasis. This study aims to investigate the association of bronchodilator response (BDR) and clinical parameters in bronchiectasis, and the utility of BDR to indicate lung function decline and risks of bronchiectasis exacerbations (BEs).

METHODS

We recruited 129 patients with clinically stable bronchiectasis. Baseline measurements included assessment of sputum inflammation and matrix metalloproteinase-8 and -9, sputum bacterial culture, spirometry, bronchial dilation test (for baseline FEV1 less than 80% predicted only) and chest high-resolution computed tomography (HRCT). Bronchiectasis patients were followed-up for 1 year to determine the incidence of BEs and lung function trajectories. Significant BDR was defined as FEV1 improvement from pre-dose value by at least 200 mL and 12%. Clinical trial registry No.: NCT01761214; URL: www.clinicaltrials.gov.

RESULTS

BDR was negatively correlated with baseline FEV1 percentage predicted, but not blood or sputum eosinophil count. Significant BDR was not associated with greater proportion of never-smokers, poorer past history, greater HRCT scores, poorer diffusing capacity or increased sputum matrix metalloproteinases (all P>0.05). There was a trend towards higher bronchiectasis severity index (BSI) and greater proportion of patients with Pseudomonas aeruginosa isolation or infection. Significant BDR at baseline was linked to poorer spirometry, but not more rapid lung function decline, throughout follow-up. Patients with significant BDR demonstrated non-significantly lower risks of experiencing the first BEs than those without (P=0.09 for log-rank test).

CONCLUSIONS

Significant BDR is associated with poorer lung function compared with non-significant BDR. Whether BDR predicts future risks of BEs needs to be tested in a larger cohort.

Для цитирования: Guan Wei-Jie, Gao Yong-Hua, Xu Gang, Li Hui-Min, Yuan Jing-Jing, Zheng Jin-Ping, Chen Rong-Chang, Zhong Nan-Shan. Bronchodilator response in adults with bronchiectasis: correlation with clinical parameters and prognostic implications.. Journal of thoracic disease. 2016. DOI: 10.3978/j.issn.2072-1439.2016.01.05.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.