MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000542081

Медицинская библиотека · Ophthalmic research · 2024

Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients.

Khoo Phong Yue, Lam Chenshen, Tang Seng Fai, Perera Shamira, Cheng Teck Chee, Md Din Norshamsiah

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

This study investigated the intraocular pressure (IOP) fluctuation as assessed by the water drinking test (WDT) in open-angle glaucoma (OAG) patients after combined cataract surgery with iStent implantation.

METHODS

This was a prospective non-randomized comparative study. Eyes with OAG and cataracts that were planned for either combined phacoemulsification and iStent implantation (iStent+CS) or phacoemulsification alone (CS) were recruited. The iStent inject (Model G2-M-IS) or iStent injectW (Model G2-W) trabecular micro-bypass stent (Glaukos Corporation, San Clemente, CA, USA) was implanted in the iStent+CS group. WDT was performed before and 3 months after surgery. WDT-IOP parameters including peak IOP, IOP fluctuation, and area under the curve (AUC) were compared between the two groups.

RESULTS

There were 20 eyes in the iStent+CS group and 16 eyes in the CS group. Both groups had similar pre-operative baseline IOP (15.6 ± 3.7 mm Hg vs. 15.8 ± 1.8 mm Hg in the iStent+CS and CS group, respectively, p = 0.883). The iStent+CS group experienced greater numerical reduction in peak IOP (2.6 ± 1.9 mm Hg vs. 1.9 ± 2.4 mm Hg; p = 0.355), IOP fluctuation (1.7 ± 2.2 mm Hg vs. 0.8 ± 2.5 mm Hg; p = 0.289), and AUC (54.8 ± 103.6 mm Hg × minute vs. 25.3 ± 79.0 mm Hg × minute; p = 0.355) than the CS group. There was more reduction in the number of anti-glaucoma medications in the iStent+CS group (1.4 ± 1.2) than the CS group (0.3 ± 0.9; p = 0.005).

CONCLUSION

Both combined phacoemulsification with iStent inject implantation and phacoemulsification alone reduced peak IOP, IOP fluctuation, and AUC, and none of these parameters showed statistically significant difference. Greater reduction in anti-glaucoma medications was seen in the combined group.

Для цитирования: Khoo Phong Yue, Lam Chenshen, Tang Seng Fai, Perera Shamira, Cheng Teck Chee, Md Din Norshamsiah. Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients.. Ophthalmic research. 2024. DOI: 10.1159/000542081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.