Visual Outcomes and Patient Satisfaction of Enhanced Monofocal Intraocular Lens in Phacovitrectomy for Idiopathic Epiretinal Membrane.

Choi Ji Youn, Won Yeo Kyoung, Lee Soo Jin, Kang Se Woong, Lim Dong Hui

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To evaluate the clinical outcomes and patient satisfaction after implantation of an enhanced monofocal intraocular lens (TECNIS Eyhance ICB00) in patients with idiopathic epiretinal membrane (ERM) who underwent cataract surgery with pars plana vitrectomy (PPV).

METHODS

This is a single-center, retrospective, comparative study. In total, 61 eyes of 61 patients with idiopathic ERM and cataracts were included. We measured the uncorrected near and intermediate visual acuity (UNVA and UIVA), uncorrected and corrected distance visual acuity (UDVA and CDVA), central macular thickness, defocus curves, and contrast sensitivity 3-6 months after the surgery. Overall patient satisfaction was assessed using a questionnaire at the 1-month follow-up visit.

RESULTS

The ICB00 group showed better near and intermediate visual acuity than the monofocal group (TECNIS ZCB00); however, no statistically significant differences were found between the groups. The ICB00 group exhibited wider defocus curves at near to far distances (-3.0 to +2.0 D) than the ZCB00 group. There were no significant differences in the results of the contrast sensitivity test, dysphotopsia, spectacle dependence, or patient satisfaction between the two groups.

CONCLUSIONS

In combined PPV and cataract surgery for ERM patients, ICB00 resulted in good visual acuity with a smoother defocus curve compared to the ZCB00 group.

Для цитирования: Choi Ji Youn, Won Yeo Kyoung, Lee Soo Jin, Kang Se Woong, Lim Dong Hui. Visual Outcomes and Patient Satisfaction of Enhanced Monofocal Intraocular Lens in Phacovitrectomy for Idiopathic Epiretinal Membrane.. Bioengineering (Basel, Switzerland). 2024. DOI: 10.3390/bioengineering11090939.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.