Comparative Analysis of Refractive Outcomes Following Cataract Surgery Using IOL Master 500 and IOL Master 700 Biometry Devices: A Retrospective Analysis.

Arens Sebastian, Böhringer Daniel, Lapp Thabo, Reinhard Thomas, Heinzelmann-Mink Sonja

СтатьяПеревод пока не подготовлен

Аннотация

Background

This study aims to compare the refractive outcomes of cataract surgery using two different biometry devices, the IOL Master 500 and IOL Master 700, and to investigate the influence of patient-related factors on these outcomes.

Methods

In this retrospective study, we analyzed data from 2994 eyes that underwent cataract surgery. Multiple linear regression analyses were performed to examine the impact of the biometry device (IOL Master 500 or IOL Master 700), patient age, time elapsed between biometry and surgery, gender, and insurance status, as well as biometric parameters (anterior chamber depth, axial length, and corneal curvature), on postoperative refractive outcomes, specifically the deviation from target refraction.

Results

The choice of the IOL Master device did not result in a statistically significant difference between the two devices (p = 0.205). Age (p = 0.006) and gender (p = 0.001) were identified as significant predictors of refractive outcomes, with older patients and males experiencing slightly more hyperopic outcomes compared to younger patients and females, respectively. The time elapsed between biometry and surgery and insurance status did not significantly influence the refractive outcomes.

Conclusions

Our study, supported by a large cohort and a diverse group of patients representing typical anatomical variants seen in cataract surgery, supports the thesis that the IOL Master 500 and IOL Master 700 can be regarded as equivalent and effective for biometry in cataract surgery. The differences between the devices were negligible. Therefore, switching between the devices is safe for bilateral patients.

Для цитирования: Arens Sebastian, Böhringer Daniel, Lapp Thabo, Reinhard Thomas, Heinzelmann-Mink Sonja. Comparative Analysis of Refractive Outcomes Following Cataract Surgery Using IOL Master 500 and IOL Master 700 Biometry Devices: A Retrospective Analysis.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13175125.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.