Refractive Predictability of Two Intraocular Lens Power Formulas in Long, Medium, and Short Eyes Using a Swept Source Optical Coherence Tomography Biometer.

Blehm Clayton, Balest Zach, Blehm Ashton C, Hall Brad

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the refractive predictability of Argos measurements with Barrett Universal II (BUII) and Barrett True Axial Length (BTAL) formulas in a large sample of long, medium, and short axial length (AL) eyes.

METHODS

A retrospective chart review identified 445 eyes of 247 patients for inclusion. The Argos was used for preoperative biometry, and BUII formula for intraocular lens (IOL) power calculations. Back calculations were performed using data from the Argos for the BTAL formula. Data were collected for postoperative absolute prediction error (APE), refractive outcomes, and monocular uncorrected and distance corrected visual acuities at distance (UDVA, CDVA).

RESULTS

Overall, mean APE was 0.36 ± 0.33 D for BUII and for 0.34 ± 0.32 D BTAL (p = 0.04). In short AL eyes, mean APE was 0.45 ± 0.37 D for BUII and for 0.37 ± 0.31 D BTAL (p < 0.001). No significant differences between BUII and BTAL were identified for long AL or medium AL eyes. The percentages of eyes with APE of 0.5 D or less in long, medium, and short eyes were 79%, 79% and 51%, respectively, for BUII and 82%, 78% and 69%, respectively, for BTAL.

CONCLUSION

The prediction accuracies were high with both the BUII and BTAL formulas in long, medium, and short eyes, leading to excellent refractive outcomes. The BTAL formula may have lower absolute prediction error in short eyes compared to BUII.

Для цитирования: Blehm Clayton, Balest Zach, Blehm Ashton C, Hall Brad. Refractive Predictability of Two Intraocular Lens Power Formulas in Long, Medium, and Short Eyes Using a Swept Source Optical Coherence Tomography Biometer.. Clinical ophthalmology (Auckland, N.Z.). 2024. DOI: 10.2147/opth.s470158.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.