MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5114/ait.2020.100574

Медицинская библиотека · Anaesthesiology intensive therapy · 2020

SpO2, heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery - a single-centre study.

Czeszyńska Maria Beata, Sontowska Agnieszka

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

SpO2, heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units.

Objective

to determine the relationship between the aforementioned parameters and the status of newborns depending on the outcome of the Infant Flow (I-F) therapy, and the development of complications in the form of pneumothorax.

MATERIAL AND

METHODS

A retrospective single-centre study covering the years 2009-2014. A total of 182 neonates, with mean gestational age 34.1 weeks and mean body weight 2226 g, were analysed. The minimum and maximum values of the evaluated parameters were analysed statistically according to the therapy outcome noted as success or failure.

RESULTS

A successful outcome of I-F therapy (71.4%) was characterised by higher SpO2 (93.3 ±7.28 vs. 85.9 ±14.77 at P < 0.001; 99.95 ±0.31 vs. 98.6 ±3.30 at P < 0.0001), lower heart rate (122.5 ±12.37 vs. 135.9 ±14.97 at P < 0.0001), and higher max systolic blood pressure (79.05 ±12.49 vs. 69.78 ±13.73 mm Hg at P < 0.0001), max diastolic blood pressure (57.03 ±9.31 vs. 50.41 ±13.82 mm Hg; P < 0.0003), and max as well as min mean arterial blood pressure (46.8 ±10.13 vs. 41.39 ±15.46 mm Hg; P < 0.001) (27.88 ±5.71 vs. 26.14 ±7.35 mm Hg; P < 0.02).

CONCLUSIONS

In newborns suffering from respiratory failure and treated with I-F, higher SpO2 values, lower heart rate, and higher arterial blood pressure coincide with success of the I-F therapy.

Для цитирования: Czeszyńska Maria Beata, Sontowska Agnieszka. SpO2, heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery - a single-centre study.. Anaesthesiology intensive therapy. 2020. DOI: 10.5114/ait.2020.100574.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.