MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/jhd-170269

Медицинская библиотека · Journal of Huntington's disease · 2017

Validation of Ultrasensitive Mutant Huntingtin Detection in Human Cerebrospinal Fluid by Single Molecule Counting Immunoassay.

Fodale Valentina, Boggio Roberto, Daldin Manuel, Cariulo Cristina, Spiezia Maria Carolina, Byrne Lauren M, Leavitt Blair R, Wild Edward J, Macdonald Douglas, Weiss Andreas, Bresciani Alberto

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The measurement of disease-relevant biomarkers has become a major component of clinical trial design, but in the absence of rigorous clinical and analytical validation of detection methodology, interpretation of results may be misleading. In Huntington's disease (HD), measurement of the concentration of mutant huntingtin protein (mHTT) in cerebrospinal fluid (CSF) of patients may serve as both a disease progression biomarker and a pharmacodynamic readout for HTT-lowering therapeutic approaches. We recently published the quantification of mHTT levels in HD patient CSF by a novel ultrasensitive immunoassay-based technology and here analytically validate it for use.

OBJECTIVE

This work aims to analytically and clinically validate our ultrasensitive assay for mHTT measurement in human HD CSF, for application as a pharmacodynamic biomarker of CNS mHTT lowering in clinical trials.

METHODS

The single molecule counting (SMC) assay is an ultrasensitive bead-based immunoassay where upon specific recognition, dye-labeled antibodies are excited by a confocal laser and emit fluorescent light as a readout. The detection of mHTT by this technology was clinically validated following established Food and Drug Administration and European Medicine Agency guidelines.

RESULTS

The SMC assay was demonstrated to be accurate, precise, specific, and reproducible. While no matrix influence was detected, a list of interfering substances was compiled as a guideline for proper collection and storage of patient CSF samples. In addition, a set of recommendations on result interpretation is provided.

CONCLUSIONS

This SMC assay is a robust and ultrasensitive method for the relative quantification of mHTT in human CSF.

Для цитирования: Fodale Valentina, Boggio Roberto, Daldin Manuel, Cariulo Cristina, Spiezia Maria Carolina, Byrne Lauren M, Leavitt Blair R, Wild Edward J, Macdonald Douglas, Weiss Andreas, Bresciani Alberto. Validation of Ultrasensitive Mutant Huntingtin Detection in Human Cerebrospinal Fluid by Single Molecule Counting Immunoassay.. Journal of Huntington's disease. 2017. DOI: 10.3233/jhd-170269.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.