Phenolic Preservatives Are Not the Sole Cause of Eosinophilic Infiltration at Infusion Pump Sites.

Cunegundes Priscila Silva, Wood Kenneth, Mao Li, Menkes Ulrike

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Background

Skin reactions and discomfort associated with insulin infusion pumps limit user adherence. A recent histopathological study by Kalus et al. (DERMIS study) reported increased eosinophilic infiltration and imputed an inflammatory response to an allergen delivered at the catheter tip. This finding might explain the pruritus reported by pump users. As eosinophils migrate to inflammatory foci, primarily due to IL-5 and CCL11, we aimed to evaluate insulin phenolic preservative (IPP) as a potential allergen in vitro and assess tissue eosinophilic infiltration in vivo.

Methods

Histopathological evaluations for eosinophil recruitment were performed over 1 week following IPP infusions in swine tissue. Additional histopathological investigations of eosinophilic infiltration were conducted using three commercial glucose sensors implanted in swine for up to 3 weeks.

Results

Eosinophilic infiltration in the dermis and subcutaneous tissue was observed following saline and IPP infusion and at glucose sensor implantation at all time points examined. In vitro studies revealed IPP eosinophil cytotoxicity. However, neither CCL11 nor IL-5 was detected in any of the tested tissue cells after IPP treatment.

Conclusion

These findings suggest that IPP is not the only triggering allergen, as IPP did not induce eosinophils in vitro, while glucose sensors also indicated increased eosinophilic infiltration. Therefore, factors other than IPP trigger eosinophil recruitment to insulin infusion pump sets.

Для цитирования: Cunegundes Priscila Silva, Wood Kenneth, Mao Li, Menkes Ulrike. Phenolic Preservatives Are Not the Sole Cause of Eosinophilic Infiltration at Infusion Pump Sites.. Diabetes technology & therapeutics. 2025. DOI: 10.1089/dia.2025.0043.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.