MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.125.014026

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2025

Feasibility and Safety of Pulsed Field Ablation for Coronary Sinus and Left Atrial Appendage Isolation and Mitral Isthmus Ablation: Acute and Chronic Findings.

La Fazia Vincenzo Mirco, Mohanty Sanghamitra, Gianni Carola, Zito Elio, Pierucci Nicola, Stifano Giuseppe, Torlapati Preem Geeta, Della Rocca Domenico G, Bode Weeranun Dechyapirom, Burkhardt J David, Horton Rodney, Al-Ahmad Amin, Di Biase Luigi, Natale Andrea

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The safety and efficacy of pulsed field ablation for pulmonary vein and posterior wall isolation in atrial fibrillation ablation are well established; however, evidence regarding its use in extra-pulmonary vein areas remains limited. The aim of this study was to assess the feasibility and durability of pulsed field ablation for coronary sinus (CS) and left atrial appendage (LAA) isolation and mitral isthmus (MI) ablation.

METHODS

We analyzed data from consecutive patients who underwent repeat atrial fibrillation ablation with pulsed field ablation between February and October 2024. MI ablation, CS isolation, and LAA isolation were attempted in all patients using the Farapulse (Boston Scientific) ablation system. Acute isolation was assessed after a 20-minute waiting period and an adenosine challenge, while chronic durability was evaluated during a repeat procedure for LAA closure at 3 months.

RESULTS

A total of 236 patients (145, 61.4% men) were included in our analysis. Acute CS isolation was achieved in 147 (62.2%) patients for the CS and in all patients for the LAA. Acute MI block was obtained in all patients. After a 20-minute waiting time, the adenosine challenge revealed dormant conduction in 52 (26.4%) cases for the CS, in 4 (1.7%) for the LAA, and MI block regression in 35 (14.8%). All patients underwent remapping at the time of left atrial appendage occlusion, which showed CS and LAA isolation in only 3 (1.3%) and 10 (4.6%) patients, respectively, and MI block in 13 (5.5%) cases.

CONCLUSIONS

Pulsed field ablation is a feasible and acutely effective method for CS and LAA isolation and MI block; however, lesion durability remains a significant limitation.

Для цитирования: La Fazia Vincenzo Mirco, Mohanty Sanghamitra, Gianni Carola, Zito Elio, Pierucci Nicola, Stifano Giuseppe, Torlapati Preem Geeta, Della Rocca Domenico G, Bode Weeranun Dechyapirom, Burkhardt J David, Horton Rodney, Al-Ahmad Amin, Di Biase Luigi, Natale Andrea. Feasibility and Safety of Pulsed Field Ablation for Coronary Sinus and Left Atrial Appendage Isolation and Mitral Isthmus Ablation: Acute and Chronic Findings.. Circulation. Arrhythmia and electrophysiology. 2025. DOI: 10.1161/circep.125.014026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.