INTRODUCTION

A single cross-finger flap can only address digital defects of a limited size, and larger defects often require distant flaps such as abdominal or groin flaps that are cumbersome to perform and sometimes bulky. Two cross-finger flaps harvested from the same donor digit could offer a simple and effective solution for many such defects. In this study, we describe the technique of monodigital double cross-finger flaps and its clinical applicability, with evaluation of donor and recipient site morbidity.

METHODS AND MATERIALS: A total of 10 subjects with large volar defects were included in the study. The demographic data, etiology, defect size, flap donor, and recipient sites were tabulated prior to surgery. Each subject was assessed for postoperative complications at the donor and recipient site and followed up for 6-12 months to document any flap or donor site morbidities.

RESULTS

The subjects included 9 males and 1 female subjects, with an average age of 35.6 years (21-67 years). Most patients had posttraumatic defects, with 3 cases of full thickness burns and one with postsurgical tissue necrosis. All defects were volar, with 4 on the little finger, 3, 2, and 1 in the ring, index and middle fingers, respectively. No major postoperative complications were noted in any case. All flaps survived well with good contour, and donor fingers achieved near-normal range of flexion with only minimal restriction (10-15°) at the distal interphalangeal joint that did not result in any overall functional disability.

CONCLUSIONS

Monodigital double cross-finger flap technique offers a simple and effective solution for reconstruction of large digital defects that are not amenable for closure by a classical cross-finger flap, and is a good alternative for other procedures, providing supple soft tissue coverage and no significant morbidity at the donor digit provided that there is preservation of a small skin bridge across the proximal interphalangeal joint.

Для цитирования: Kakola Mohan G, N Vijaykumar, Ms Chandrashekar. Monodigital Double Cross-Finger Flaps-A Novel Approach for Coverage of Large Volar Defects.. Annals of plastic surgery. 2024. DOI: 10.1097/sap.0000000000003995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.