MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08037051.2021.1922267

Медицинская библиотека · Blood pressure · 2021

Continuous positive airway pressure adherence and blood pressure lowering in patients with obstructive sleep apnoea syndrome and nocturnal hypertension.

Xia Jia-Hui, Kang Yuan-Yuan, Cheng Yi-Bang, Huang Qi-Fang, Xu Ting-Yan, Li Yan, Wang Ji-Guang

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We investigated continuous positive airway pressure (CPAP) adherence and its association with the blood pressure (BP) and pulse rate changes in patients with obstructive sleep apnoea syndrome (OSAS) and hypertension.

MATERIALS AND

METHODS

In a single-blind trial, patients were randomly assigned to CPAP or sham CPAP treatment for 3 months. We performed clinic, ambulatory and home BP measurements at baseline and during follow-up. CPAP adherence was assessed as the CPAP frequency per week and time per night. Non-adherence was defined as a CPAP use for <5 days/week or <4 h/night.

RESULTS

In the CPAP (n = 26) and sham CPAP groups (n = 21), the CPAP frequency was 5.5 and 4.8 days/week (p = 0.17), respectively, and the CPAP time was 5.0 and 4.1 h/night (p = 0.03), respectively. The corresponding prevalence of non-adherence was 46.2% and 66.7% (p = 0.16), respectively. The CPAP frequency but not time tended to be associated with the changes in BP and pulse rate at 3 months of follow-up, especially home systolic/diastolic BP in the CPAP group (3.2/1.3 mmHg greater reductions per 1 day increment, p ≤ 0.01). Adherent, compared with non-adherent patients, had greater reductions in BP or pulse rate at 3 months of follow-up. In the CPAP and sham CPAP groups combined, statistical significance was achieved for the adjusted between adherence and non-adherence differences in home systolic/diastolic BP (-5.0/-3.8 mmHg) and 24-h, daytime and night-time ambulatory pulse rate (-6.2, -7.8 and -4.4 beats/min, respectively, p ≤ 0.04).

CONCLUSION

CPAP adherence was associated with the BP lowering and pulse rate slowing effects, especially the CPAP frequency.

Для цитирования: Xia Jia-Hui, Kang Yuan-Yuan, Cheng Yi-Bang, Huang Qi-Fang, Xu Ting-Yan, Li Yan, Wang Ji-Guang. Continuous positive airway pressure adherence and blood pressure lowering in patients with obstructive sleep apnoea syndrome and nocturnal hypertension.. Blood pressure. 2021. DOI: 10.1080/08037051.2021.1922267.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.