MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1183/23120541.00340-2020

Медицинская библиотека · ERJ open research · 2021

Validation of the Swedevox registry of continuous positive airway pressure, long-term mechanical ventilator and long-term oxygen therapy.

Ekström Magnus, Albrecht Dirk, Andersson Susanne, Grote Ludger, Kärrsten Rundström Birgitta, Palm Andreas, Theorell-Haglöw Jenny, Wahlberg Josefin, Midgren Bengt

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Swedish Registry of Respiratory Failure (Swedevox) collects nationwide data on patients starting continuous positive airway pressure (CPAP) treatment, long-term mechanical ventilator (LTMV) and long-term oxygen therapy (LTOT). We validated key information in Swedevox against source data from medical records.

METHODS

This was a retrospective validation study of patients starting CPAP (n=175), LTMV (n=177) or LTOT (n=175) across seven centres 2013-2017. Agreement with medical record data was analysed using differences in means (sd) and proportion (%) of a selection of clinically relevant variables. Variables of interest included for CPAP: apnoea-hypopnoea index (AHI), height, weight, body mass index (BMI) and Epworth Sleepiness Scale (ESS) score; for LTMV: date of blood gas, arterial carbon dioxide tension (P aCO2 ) (breathing air), weight and diagnosis group; and for LTOT: blood gases breathing air and oxygen, spirometry and main diagnosis.

RESULTS

Data on CPAP and LTOT had very high validity across all evaluated variables (all <5% discrepancy). For LTMV, variability was higher against source information for P aCO2 (>0.5 kPa in 25.9%), weight (>5 kg in 47.5%) and diagnosis group. Inconsistency was higher for patients starting LTMV acutely versus electively (P aCO2 difference >0.5 kPa in 36% versus 21%, p<0.05, respectively). However, there were no signs of systematic bias (mean differences close to zero) across the evaluated variables.

CONCLUSION

Validity of Swedevox data, compared with medical records, was very high for CPAP, LTMV and LTOT. The large sample size and lack of systematic differences support that Swedevox data are valid for healthcare quality assessment and research.

Для цитирования: Ekström Magnus, Albrecht Dirk, Andersson Susanne, Grote Ludger, Kärrsten Rundström Birgitta, Palm Andreas, Theorell-Haglöw Jenny, Wahlberg Josefin, Midgren Bengt. Validation of the Swedevox registry of continuous positive airway pressure, long-term mechanical ventilator and long-term oxygen therapy.. ERJ open research. 2021. DOI: 10.1183/23120541.00340-2020.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.