DOI 10.1371/journal.pone.0178936

Медицинская библиотека · PloS one · 2017

18F-FDG silicon photomultiplier PET/CT: A pilot study comparing semi-quantitative measurements with standard PET/CT.

Baratto Lucia, Park Sonya Young, Hatami Negin, Davidzon Guido, Srinivas Shyam, Gambhir Sanjiv Sam, Iagaru Andrei

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate if the new Discovery Molecular Insights (DMI) PET/CT scanner provides equivalent results compared to the standard of care PET/CT scanners (GE Discovery 600 or GE Discovery 690) used in our clinic and to explore any possible differences in semi-quantitative measurements.

METHODS

The local Institutional Review Board approved the protocol and written informed consent was obtained from each patient. Between September and November 2016, 50 patients underwent a single 18F-FDG injection and two scans: the clinical standard PET/CT followed immediately by the DMI PET/CT scan. We measured SUVmax and SUVmean of different background organs and up to four lesions per patient from data acquired using both scanners.

RESULTS

DMI PET/CT identified all the 107 lesions detected by standard PET/CT scanners, as well as additional 37 areas of focal increased 18F-FDG uptake. The SUVmax values for all 107 lesions ranged 1.2 to 14.6 (mean ± SD: 2.8 ± 2.8), higher on DMI PET/CT compared with standard of care PET/CT. The mean lesion:aortic arch SUVmax ratio and mean lesion:liver SUVmax ratio were 0.2-15.2 (mean ± SD: 3.2 ± 2.6) and 0.2-8.5 (mean ± SD: 1.9 ± 1.4) respectively, higher on DMI PET/CT than standard PET/CT. These differences were statistically significant (P value < 0.0001) and not correlated to the delay in acquisition of DMI PET data (P < 0.0001).

CONCLUSIONS

Our study shows high performance of the new DMI PET/CT scanner. This may have a significant role in diagnosing and staging disease, as well as for assessing and monitoring responses to therapies.

Для цитирования: Baratto Lucia, Park Sonya Young, Hatami Negin, Davidzon Guido, Srinivas Shyam, Gambhir Sanjiv Sam, Iagaru Andrei. 18F-FDG silicon photomultiplier PET/CT: A pilot study comparing semi-quantitative measurements with standard PET/CT.. PloS one. 2017. DOI: 10.1371/journal.pone.0178936.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.