MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1162/imag.a.1328

Медицинская библиотека · Imaging neuroscience (Cambridge, Mass.) · 2026

A robust and reproducible automated MRI pipeline for quantifying tissue outcomes after experimental stroke in multi-center preclinical networks.

Lynch Kirsten M, Cabeen Ryan P, de Morais Andreia Lopes, Jin Xuyan, Tarakci Erendiz, Lamb Jessica, Sanganahalli Basavaraju G, Mihailovic Jelena M, Olivas-Garcia Yamileck, Berry David B, Diniz Marcio A, Mandeville Joseph, Hyder Fahmeed, Thedens Daniel R, Arbab Ali, Huang Shuning, Bibic Adnan, Austin Wyatt, Hu Bingren, Khan Mohammad B, Kamat Pradip K, Toga Arthur W, Lyden Patrick, Ayata Cenk

СтатьяПеревод пока не подготовлен

Аннотация

The failure to translate promising preclinical stroke therapies into clinical success is a multi-faceted problem; however, a critical contributing factor is the lack of rigorous, reproducible preclinical outcome measures. While magnetic resonance imaging (MRI) offers a translational alternative to traditional histology, its use in large, multi-site trials is challenged by data heterogeneity and the need for scalable analysis. To address this, we developed and validated a fully automated, open-source image analysis pipeline for the Stroke Preclinical Assessment Network (SPAN), a six-center preclinical trial network. The pipeline processed T2-weighted and apparent diffusion coefficient (ADC) maps from over 2,000 mice and rats, incorporating steps for cross-site data harmonization, deep learning-based brain extraction, and rule-based segmentation to quantify infarct volume, brain swelling, and atrophy. The pipeline demonstrated high accuracy, as automated lesion volumes strongly correlated with manual expert tracing on both MRI (R = 0.96) and 2,3,5-triphenyl-tetrazolium chloride (TTC)-stained tissue (R = 0.86). The U-net model for brain extraction achieved a Dice score of 0.96, and our harmonization method successfully reduced inter-site variability in quantitative MRI parameters. This robust and reproducible pipeline provides a scalable framework for standardizing tissue outcome assessment, enhancing the rigor of multi-site preclinical studies.

Для цитирования: Lynch Kirsten M, Cabeen Ryan P, de Morais Andreia Lopes, Jin Xuyan, Tarakci Erendiz, Lamb Jessica, Sanganahalli Basavaraju G, Mihailovic Jelena M, Olivas-Garcia Yamileck, Berry David B, Diniz Marcio A, Mandeville Joseph, Hyder Fahmeed, Thedens Daniel R, Arbab Ali, Huang Shuning, Bibic Adnan, Austin Wyatt, Hu Bingren, Khan Mohammad B, Kamat Pradip K, Toga Arthur W, Lyden Patrick, Ayata Cenk. A robust and reproducible automated MRI pipeline for quantifying tissue outcomes after experimental stroke in multi-center preclinical networks.. Imaging neuroscience (Cambridge, Mass.). 2026. DOI: 10.1162/imag.a.1328.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.