Suprascapular Neuropathy From Malpositioned Baseplate Screws in Primary Reverse Shoulder Arthroplasty: Two Case Reports.
Аннотация
CASES: Two patients presented to different surgeons complaining of persistent shoulder pain after reverse total shoulder arthroplasty. Workups for fracture, instability, and periprosthetic infection were negative. Advanced imaging, nerve conduction studies, and diagnostic injections localized symptoms to the suprascapular nerve. Revision arthroplasty with removal of the offending screws improved pain in both patients.
CONCLUSION
Suprascapular nerve irritation because of the malposition of baseplate screws in reverse total shoulder arthroplasty can be a source of postoperative pain. Removal of the offending screw without formal nerve exploration may result in symptomatic improvement.