Time trends of some indicators of mammography screening programmes in Italy, 1996-2003.

Giordano Livia, Giorgi Daniela, Piccini Paola, Stefanini Valeria, Castagno Roberta, Senore Carlo

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

Since 1992, the Italian Group for Mammography Screening (GISMa) has been performing a yearly systematic survey of ongoing activities. The screening extension increased from 1996, reaching an overall 68.7% coverage in 2004. This progression has been more evident in Central-Northern Italy while in Southern Italy a real, but still limited (30%), increase has been recorded only recently. Despite this geographical extension, the actual coverage reached only 5 1.1% of the target population, due to a reduced flow of invitations over time as a consequence of a chronic lack of invested resources and of well planned political actions. The time trends for the key performance indicators show a good average performance: crude attendance rate exceeds over the years the acceptable 50% standard; BIM ratio is progressively decreasing, reaching a ratio of 0.7:1 (both for first/subsequent screening) in 2003; overall detection rate, detection rate for in situ and small cancers (< or =10 mm) show a good trend, reaching 6.6% per hundred, 1.5% per hundred and 0.7% per hundred respectively for the first screening in 2003. An exception is the referral rate at first screening which exceeds the reference standards (> 7% in the last 2 years). Data have been analysed also according to activity volume and programme duration. In programmes with greater activity (average test number: 24,702) the referral rate for the first screening is higher, but still within acceptable standards: 5.8%; RR: 1.05 (1.02-1.10). This performance is compensated by better specificity and sensitivity: PPV = 13.3: RR: 1.14 (1.03-1.27); overall detection rate = 6.7% per hundred; RR: 1.22 (1.09-1.36). An improvement of quality with the increase of experience is evident: programmes with more than 6 years of activity, compared with newer programmes, show a recall rate in first screening of 6.0%; RR:0.86 (0.86-0.92), a PPV of 13.4; RR: 1.65 (1.40-1.69) and an overall detection rate of 8.1% per hundred; RR: 1.44 (1.25-1.53). These results are consistent with those observed in other European programmes, and encourage new analysis strategies. The web site of the National Centre for Monitoring Screening is http://wwuw.osservatoriotumori.it.

Для цитирования: Giordano Livia, Giorgi Daniela, Piccini Paola, Stefanini Valeria, Castagno Roberta, Senore Carlo. Time trends of some indicators of mammography screening programmes in Italy, 1996-2003.. Epidemiologia e prevenzione. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.