MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10334-026-01370-7

Медицинская библиотека · Magma (New York, N.Y.) · 2026

Fat-suppressed quantitative ultrashort echo time magnetization transfer (UTE-MT) imaging of the knee joint.

Shin Soo Hyun, Athertya Jiyo S, Wang Jiaji, Lo James, Statum Sheronda M, Chung Christine B, Ma Yajun, Du Jiang

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To develop a simple fat-suppression strategy for more accurate quantitative ultrashort echo time magnetization transfer (UTE-MT) imaging of knee joint tissues.

MATERIALS AND

METHODS

A narrow-bandwidth RF pulse centered on the fat peak was utilized for fat-selective imaging. These fat-selective images were subsequently subtracted from the MT-weighted 3D-UTE images to mitigate fat contamination in knee joint tissue imaging. This method was evaluated in an ex vivo human knee specimen and in three healthy volunteers at 3 T. Voxel-wise and ROI-based quantitative MT modeling were both performed to estimate macromolecular fraction (MMF), and results with and without fat suppression were compared.

RESULTS

Fat-selective images revealed off-resonance artifacts from surrounding fatty tissues that extended into adjacent joint structures. Subtraction of the fat-selective images effectively suppressed these artifacts and improved visualization of cartilage, meniscus, and tendons. In ex vivo data, fat suppression stabilized MMF estimates by correcting voxels with abnormally elevated values (> 50%). MMF values were increased after fat suppression in articular cartilage (11.9 ± 1.3% vs. 17.3 ± 1.5%), meniscus (15.9 ± 0.8% vs. 18.2 ± 1.9%), patellar cartilage (13.5 ± 1.0% vs. 18.3 ± 0.4%), and patellar tendon (17.4 ± 2.8% vs. 24.6 ± 0.4%). Tissue contrast-to-noise ratios were also markedly improved.

DISCUSSION: Subtraction of fat-selective images provides a simple and effective approach for suppressing fat interference in UTE-MT imaging, improving both image contrast and MT measurements.

Для цитирования: Shin Soo Hyun, Athertya Jiyo S, Wang Jiaji, Lo James, Statum Sheronda M, Chung Christine B, Ma Yajun, Du Jiang. Fat-suppressed quantitative ultrashort echo time magnetization transfer (UTE-MT) imaging of the knee joint.. Magma (New York, N.Y.). 2026. DOI: 10.1007/s10334-026-01370-7.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.