OBJECTIVE

To describe a technique for tracheostomy in heterotopic ossification that has not yet been described in the literature.

METHODS

We report a case of difficult tracheostomy while using conventional techniques in a 68-year-old patient who underwent mitral valve replacement requiring warfarin therapy three months prior. Imaging revealed heterotopic ossification overlying the trachea. A literature review was performed to identify similar cases or techniques.

RESULTS

Extensive surgical planning was pursued after the initial attempted tracheostomy failed, and the airway was eventually accessed using a lighted intubation stylet for guidance and a drill. Heterotopic ossification has been described after orthopedic and abdominal surgeries. We identified one case report in the literature of tracheostomy performed in the setting of heterotopic ossification by an unspecified mechanism. There are few reported cases of tracheobronchial calcification in cardiac patients receiving warfarin therapy; however, these patients had characteristic imaging findings that were not consistent with those of our patient.

CONCLUSIONS

We illustrate a safe and effective technique for tracheostomy in heterotopic ossification that has not been reported. Coordination with the anesthesia service was paramount for a successful operation.

Для цитирования: Cheng Esther, Thorpe Eric. A Unique Surgical Technique for Tracheostomy in Heterotopic Ossification: A Case Report.. The Annals of otology, rhinology, and laryngology. 2016. DOI: 10.1177/0003489416665193.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.