Noninvasive positive-pressure ventilation for extubation failure after cardiac surgery: Pilot safety evaluation.

De Santo Luca S, Bancone Ciro, Santarpino Giuseppe, Romano Gianpaolo, Della Corte Alessandro, Vicchio Mariano, De Pietro Antonio, Galdieri Nicola, Cotrufo Maurizio

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Extubation failure is a serious complication after cardiac surgery. The role of noninvasive positive-pressure ventilation for acute respiratory failure in patients undergoing cardiac surgery is unknown. This study aimed to assess the safety of implementing noninvasive positive-pressure ventilation in this setting and its impact on lung function and operative outcomes.

METHODS

In a 6-month pilot prospective survey, the study population comprised 43 patients (32 were male with a mean age of 65.73 +/- 9 years; 3 heart transplantations, 18 coronary artery bypass grafts, 5 aortic dissections, and 17 valvular procedures; 34 active smokers, 25 with medically treated chronic obstructive pulmonary disease, 21 emergency/urgency procedures) who required noninvasive positive-pressure ventilation for acute respiratory failure after initial weaning from a respirator. The cause of acute respiratory failure (classified as post-cardiopulmonary bypass lung injury in 48.8% [21 patients], cardiogenic edema in 30.2% [13 patients], and pneumonia in 21% [9 patients]), length of noninvasive positive-pressure ventilation support, respiratory ratios (arterial oxygen tension/fraction of inspired oxygen assessed immediately before noninvasive positive-pressure ventilation, and every 6 hours after institution of pressure ventilation), and need for reintubation along with a set of predefined safety parameters were recorded.

RESULTS

The mean length of noninvasive positive-pressure ventilation support was 33.8 +/- 24.04 hours. Plotting respiratory ratios with length of noninvasive positive-pressure ventilation supports a significant improvement was already evident within the first 6-hour frame (133.6 +/- 39.5 vs 205 +/- 65.7; P < .001) for all causes. Noninvasive positive-pressure ventilation prevented intubation in 74.4% of the patients, with satisfactory recovery for post-cardiopulmonary bypass lung injury and cardiogenic dysfunction (90.5% and 69.2%, respectively) and poor results (55% reintubated) in those treated for pneumonia. Noninvasive positive-pressure ventilation safety approached 97.7%.

CONCLUSION

In appropriate candidates, noninvasive positive-pressure ventilation exerts favorable effects on lung function, preventing reintubation. The cost-effectiveness of its systematic use in this setting should be assessed.

Для цитирования: De Santo Luca S, Bancone Ciro, Santarpino Giuseppe, Romano Gianpaolo, Della Corte Alessandro, Vicchio Mariano, De Pietro Antonio, Galdieri Nicola, Cotrufo Maurizio. Noninvasive positive-pressure ventilation for extubation failure after cardiac surgery: Pilot safety evaluation.. The Journal of thoracic and cardiovascular surgery. 2009. DOI: 10.1016/j.jtcvs.2008.07.067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.