m+Medelevator.RU
← Поиск публикаций
Journal of clinical monitoring and computing · 2025

EEG features associated with Alzheimer's disease and Frontotemporal dementia are not reflected by processed indices used in anesthesia monitoring.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schwerin Stefan, Dragovic Srdjan Z, Ostertag Julian, Nguyen Duy-Minh, Schneider Gerhard, Kreuzer Matthias

Аннотация

Patients with dementia face increased risks after general anesthesia. Improved perioperative electroencephalogram (EEG) monitoring techniques could aid in identifying vulnerable patients. However, current technology relies on processed indices to measure "depth-of-anesthesia". Analyzing OpenNeuro Dataset ds004504, we compared resting-state, eyes-closed EEG recordings of healthy controls (n = 27) with patients diagnosed with Alzheimer's disease (AD, n = 35) and Frontotemporal dementia (FTD, n = 23). We focused on prefrontal recordings. Analysis included spectral analysis, the "fitting-oscillations&-one-over-f"-algorithm for aperiodic and periodic signal features, as well as calculations of openibis, permutation entropy (PeEn), spectral entropy (SpEn), and spectral edge frequency (SEF). Spectral differences were pronounced, including a higher alpha/theta-ratio of controls (2.62 [95%CI: 1.54-3.62]) compared to both AD (0.55 [95%CI: 0.26-1.92], P < 0.001, AUC: 0.765 [0.642-0.888]) and FTD (0.83 [95%CI: 0.33-1.65], P = 0.007, AUC: 0.779 [0.652-0.907]). Oscillatory peak detection within the alpha frequency band was more robust in control (versus AD: P = 0.003, Cramér's V = 0.374; versus FTD: P = 0.003, Cramér's V = 0.414). Processed index parameters did not show a clear trend. FTD was associated with a higher prefrontal openibis (95.53 [95%CI: 93.43-97.39]) than control (91.98 [95%CI: 89.46-96.27], P = 0.033, AUC: 0.717 [0.572-0.862]) and an elevated SEF (23.68 [95%CI: 14.10-25.57] Hz) compared to AD (16.60 [95%CI: 14.22-22.22] Hz, P = 0.041, AUC: 0.676 [0.532-0.821]). AD and FTD are associated with EEG baseline abnormalities, and a standard prefrontal montage, as used intraoperatively, could present a promising technical screening approach for cognitive vulnerability. However, these EEG features are obscured by processed index parameters currently used in neuroanesthesia monitoring. OpenNeuro Dataset ds004504 "A dataset of EEG recordings from: Alzheimer's disease, Frontotemporal dementia and Healthy subjects" (doi: https://doi.org/10.18112/openneuro.ds004504.v1.0.7 ).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты