Comparison of monoblock and twinblock mandibular advancement devices in patiens with obstructive sleep apnea and temporomandibular disorder: effects on airway volume, polysomnography parameters, and sleepiness scale scores.

Özköylü Gözde, Saraç Duygu, Sasany Rafat, Umurca Dilara Gülhan

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to compare the effects of two different mandibular advancement devices on the upper airway volume, polysomnographic parameters, and sleepiness scale scores in patients with obstructive sleep apnea and Temporomandibular disorders (TMD).

MATERIALS AND

METHODS

Monoblock and twinblock mandibular advancement devices were applied to patients with obstructive sleep apnea syndrome for 3 months separated by a wash-out period of 2 weeks. Research Diagnostic Criteria for TMD (RDC/TMD), Polysomnographic parameters and cone-beam computed tomography findings were recorded before and after the use of the mandibular advancement devices. A three-dimensional analysis of the airway was then performed.

RESULTS

The use of the monoblock device significantly increased the upper airway volume compared with the use of the twinblock device (p = 0.032). The polysomnographic parameters similarly improved with the use of the twin-block and monoblock devices. The significant reduction in TMD symptoms was observed.

CONCLUSION

The use of the monoblock device increased the retropalatal airway volume. This volume increase may be attributed to the fact that the design of the monoblock device allows less mandibular movement than does that of the twinblock device. Indicates the potential benefits of MADS treatment in alleviating TMD-related issues.

CLINICAL SIGNIFICANCE: Monoblock MADs have improved effects on respiratory parameters and upper airway dimensions in patients with OSA and mild to moderate TMD.

Для цитирования: Özköylü Gözde, Saraç Duygu, Sasany Rafat, Umurca Dilara Gülhan. Comparison of monoblock and twinblock mandibular advancement devices in patiens with obstructive sleep apnea and temporomandibular disorder: effects on airway volume, polysomnography parameters, and sleepiness scale scores.. BMC oral health. 2024. DOI: 10.1186/s12903-024-04653-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.