MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000001978

Медицинская библиотека · Nuclear medicine communications · 2025

Leg-muscle perfusion reserve on 99mTc-MIBI stress-rest scintigraphy: the novel use of radionuclide imaging in assessing lower extremity functional capacity.

Singhal Tejasvini, Singh Parneet, Parida Girish Kumar, Agrawal Kanhaiyalal

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate the utility of lower extremity 99mTc-MIBI imaging as a noninvasive correlate to lower extremity functional capacity.

MATERIALS AND

METHODS

Patients referred for stress myocardial perfusion imaging with no known history of peripheral artery disease (PAD) were included in the study. 99mTc-MIBI perfusion scintigraphy was performed for calf muscles at stress and rest. Perfusion reserve (PR) for bilateral calves was calculated as: (average stress counts-average rest counts)/average rest counts × 100. Correlation of PR was assessed for functional/exercise capacity [metabolic equivalents (METs) and exercise duration].

RESULTS

Eighty-six patients (70 male and 16 female) with a median age of 53.5 (range 28-77) years were included in the study. The mean PR for calf muscles was 62.9 ± 37.9%. There was a significant correlation between the functional capacity of the patients (METs achieved and exercise duration) and PR of bilateral calf muscles.

CONCLUSION

Radionuclide imaging with 99 m-Tc MIBI allows noninvasive assessment of changes in both macrovascular and microvascular perfusion under dynamic exercise. Thus, it may serve as an ideal noninvasive imaging to provide insight into physiological adaptations as well as to detect the macrovascular and microvascular perfusion disturbances in PAD and skeletal muscle adaptation in response to exercise therapy commonly prescribed for PAD or other novel therapies.

Для цитирования: Singhal Tejasvini, Singh Parneet, Parida Girish Kumar, Agrawal Kanhaiyalal. Leg-muscle perfusion reserve on 99mTc-MIBI stress-rest scintigraphy: the novel use of radionuclide imaging in assessing lower extremity functional capacity.. Nuclear medicine communications. 2025. DOI: 10.1097/mnm.0000000000001978.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.