MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.14309

Медицинская библиотека · Veterinary surgery : VS · 2025

Ex vivo comparative evaluation of feline hilar lung lobectomy using linear stapler, pretied ligature loop, and double-shank titanium clips.

Ritson Kadi, Camarasa Juan Jose, Gregorio Maria, Vallefuoco Rosario

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the seal performance of a linear vascular stapler, pretied ligature loop (PLL), and double-shank (DS) titanium clip for total lung lobectomy in a feline cadaveric model under physiologic and supraphysiologic airway pressures.

STUDY

DESIGN

Ex vivo experimental randomized study.

SAMPLE POPULATION: Thirty cadaveric feline lung lobes.

METHODS

Thirty lung lobes from five fresh feline cadavers, humanely euthanized for reasons unrelated to this study, were randomized into three groups to undergo hilar lung lobectomy using a linear vascular stapler, PLL, or DS titanium clips. After lobectomy, each bronchial stump was submerged in water, and the peak inspiratory airway pressure was increased up to 40 cm H₂O. Bursting pressure was compared across the techniques.

RESULTS

No air leaks were observed in the PLL or DS titanium clip groups. One bronchial stump (1/10) in the linear vascular stapler group leaked at the supraphysiologic pressure of 40 cm H₂O. There was no difference in leakage incidence among the groups (p = .33).

CONCLUSION

Linear vascular stapler, PLL, or DS titanium clips were comparable and effective devices for sealing the hilar lung lobectomy site at physiologic and supraphysiologic airway pressure in feline cadavers. The PLL and DS titanium clips were relatively easy to use, required less working space, and may represent an equally effective and more cost-efficient alternative to traditional stapling devices in open and minimally invasive feline pulmonary lobectomy.

Для цитирования: Ritson Kadi, Camarasa Juan Jose, Gregorio Maria, Vallefuoco Rosario. Ex vivo comparative evaluation of feline hilar lung lobectomy using linear stapler, pretied ligature loop, and double-shank titanium clips.. Veterinary surgery : VS. 2025. DOI: 10.1111/vsu.14309.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.