MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsg.2025.02.012

Медицинская библиотека · Journal of hand surgery global online · 2025

Influence of the Tendon Grasping Technique on Tensile Strength in 6-strand Sutures.

Moriya Koji, Maki Yutaka, Koda Hisao, Kuroda Takuma, Tsubokawa Naoto

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The locking configuration of the core suture in tendon repair considerably impacts the tendon's tensile strength. This study assessed the effects of two grasping techniques for 6-strand core sutures on gap formation resistance using linear load-to-failure testing under simulated tendon loading during active finger flexion.

METHODS

Forty porcine flexor tendons were assigned to 3 groups and repaired using the Yoshizu #1 (Y1) technique or our novel 6-strand Yoshizu #3 (Y3) technique with or without peripheral sutures. The Y1 and Y3 techniques had similar suture configurations, but the Y1 technique involved 4 Kessler-type tendon anchorages and the Y3 technique 2 Lim and Tsai-type tendon grasping techniques. Repaired tendons were subjected to linear, noncyclic load-to-failure tensile testing. The initial gap, 2-mm gap force, and ultimate strength were measured.

RESULTS

Tendons repaired using the Y1 technique had a significantly lower mean load at the initial gap (9.4 N) than those repaired using the Y3 technique alone (26.8 N) and the Y3 technique with peripheral sutures (81.6 N). Average load at the 2-mm gap was greater following Y3 repair alone (38.1 N) and Y3 repair with peripheral sutures (94.3 N) than Y1 repair (22.4 N).

CONCLUSIONS

Significantly higher mean loads at the initial and 2-mm gap were obtained with the novel 6-strand Y3 technique compared to the 6-strand Y1 technique regardless of the use of peripheral sutures. These results suggested that Lim and Tsai-type tendon grasping is associated with greater gap resistance than Kessler-type tendon anchorage. In the Y3 technique, the use of peripheral sutures is particularly effective for enhancing the initial tension.

CLINICAL RELEVANCE: Surgeons should consider the impact of the tendon grasping technique on flexor tendon suturing. This novel 6-strand Y3 technique with peripheral sutures facilitates early active motion following primary flexor tendon repair.

Для цитирования: Moriya Koji, Maki Yutaka, Koda Hisao, Kuroda Takuma, Tsubokawa Naoto. Influence of the Tendon Grasping Technique on Tensile Strength in 6-strand Sutures.. Journal of hand surgery global online. 2025. DOI: 10.1016/j.jhsg.2025.02.012.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.