PURPOSE: The partial pressure of oxygen (pO2) in tissue is a tightly regulated physiological quantity. Hypoxia is a hallmark of many diseases, and changes in tissue pO2 underline critical developmental, metabolic, and physiological processes. Electron paramagnetic resonance oxygen imaging (EPROI) has emerged as the most precise technique to image pO2 in vitro and in vivo. EPROI uses linear relationship between the relaxation rates (R1 or R2) of the spin probe OXO71 and pO2.

METHODS: The current gold standard for EPROI is inversion recovery electron spin echo (IRESE) sequence with radial k-space acquisition scheme, which is fast, provides high pO2 resolution using T1 imaging, but suffers from low spatial resolution, especially at higher oxygen concentrations. The other method, single-point imaging (SPI), which uses Cartesian k-space acquisition scheme and free-induction decay (FID) readout, provides higher spatial resolution but has lower signal-to-noise ratio (SNR) and lower pO2 accuracy, especially for T2* imaging. In this work, we introduce advanced inversion-recovery single-point imaging (AIR-SPI), which combines inversion-recovery SPI (IR-SPI) with multi-point FID averaging in the spatial domain. We evaluate the performance of AIR-SPI in phantoms and in vivo imaging of a fibrosarcoma (FSA) tumor in a mouse leg.

RESULTS: We demonstrate 2-8-fold SNR improvement and higher spatial resolution for AIR-SPI compared to IR-SPI and IRESE, especially for high oxygen concentrations. We also demonstrate higher pO2 precision for AIR-SPI.

CONCLUSIONS: AIR-SPI offers improvements in image SNR, spatial, and oxygen resolution over all existing EPR oxygen imaging methods, without increasing imaging time. Importantly, it uses smaller RF power than echo-based methods, which is crucial for scaling EPROI to human applications.