MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mva.2002.120372

Медицинская библиотека · Journal of vascular surgery · 2002

Duplex scan-directed placement of inferior vena cava filters: a five-year institutional experience.

Conners Michael S, Becker Stacey, Guzman Raul J, Passman Marc A, Pierce Rosanna, Kelly Tina, Naslund Thomas C

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was the assessment of the safety, efficacy, and hospital charges of bedside duplex ultrasound-directed inferior vena cava (IVC) filter placement.

METHODS

All duplex ultrasound-directed IVC filters that were placed from August 8, 1995, to December 31, 2000, are reviewed. Chart review combined with mailed questionnaires and telephone follow-up examinations were used to collect demographic and outcome data.

RESULTS

Three hundred twenty-five patients underwent evaluation, and 284 underwent duplex ultrasound-directed IVC filter placement. Two hundred three (71%) were male patients, and 81 (29%) were female patients. Poor IVC visualization, IVC thrombosis, and unsuitable anatomy prevented duplex-directed filter placement in 41 patients (12%). Indication for filter placement included venous prophylaxis in the absence of thromboembolism in 235 patients (83%), contraindication to anticoagulation therapy in 34 patients (12%), prophylaxis with therapeutic anticoagulation therapy in the presence of thromboembolism in 7 patients (2%), and complication of anticoagulation therapy in 8 patients (3%). There were no procedure-related deaths or septic complications. Technical complications occurred in 12 patients (4%). Filter misplacement occurred in 6 patients (2%), access thrombosis in 1 (<1%), migration in 1 (<1%), bleeding in 1 (<1%), and IVC occlusion in 3 (1%). Pulmonary emboli after IVC filter placement occurred in one patient with a misplaced filter. Average hospital charges related to duplex ultrasound-directed filter placement were $2388 less than fluoroscopic placement charges in the year 2000.

CONCLUSION

Our experience indicates that duplex ultrasound-directed IVC filter placement is safe, cost-effective, and convenient for patients who need IVC filter placement.

Для цитирования: Conners Michael S, Becker Stacey, Guzman Raul J, Passman Marc A, Pierce Rosanna, Kelly Tina, Naslund Thomas C. Duplex scan-directed placement of inferior vena cava filters: a five-year institutional experience.. Journal of vascular surgery. 2002. DOI: 10.1067/mva.2002.120372.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.