MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5005/jp-journals-10005-3604

Медицинская библиотека · International journal of clinical pediatric dentistry · 2026

Evaluation of Clinical Efficiency of Two Single-file Ni-Ti Rotary Systems in Performing Root Canal Treatment in Primary Teeth: A Randomized Clinical Trial.

Lakshmidevi Lomada, Ahalya Penmetsa, Ravigna Peddi, Ramesh Manumanthu V, Himavarsha Mannam, Sivaram Sangadala

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The conventional procedure using stainless steel hand files is very time-consuming and has associated disadvantages. A literature review demonstrates the effectiveness of nickel-titanium (Ni-Ti) rotary files in this regard. Technological advancements have led to the development of various single-file Ni-Ti rotary systems, such as Kedo-S and XP-Endo Shaper.

AIM: To compare the instrumentation time and quality of obturation in primary molars, assessed by the Coll and Sadrian criteria, using two single-file Ni-Ti rotary systems, Kedo-S and XP-Endo Shaper.

MATERIALS AND

METHODS

A randomized clinical trial was conducted in children aged 4-9 years requiring single- or two-visit pulpectomy. A total of 50 primary molars were allocated into two groups of 25 each, that is, group I (Kedo-S) and group II (XP-Endo Shaper). Instrumentation time was recorded using a digital stopwatch, while the quality of obturation was assessed radiographically using the Coll and Sadrian criteria. The obtained data were subjected to statistical analysis using the Mann-Whitney U test for instrumentation time and Pearson's Chi-squared test for quality of obturation.

RESULTS

XP-Endo Shaper demonstrated a statistically significant difference in instrumentation time (p = 0.001) and a nonsignificant difference in the quality of obturation (p = 0.350). A greater percentage of optimal fills (84%) and a fewer number of voids were evident with XP-Endo Shaper.

CONCLUSION

The use of the adaptive XP-Endo Shaper resulted in reduced instrumentation time and better quality of obturation.

CLINICAL SIGNIFICANCE: Pulpectomies performed under general anesthesia, where time is a constraint, can benefit from the use of single-file rotary systems. Considering the quality of obturation, XP-Endo Shaper performed better, with fewer voids and a greater number of optimal fills due to its adaptive technology.

CTRI REG NO: CTRI/2025/04/084040.

HOW TO CITE THIS ARTICLE: Lakshmidevi L, Ahalya P, Ravigna P, et al. Evaluation of Clinical Efficiency of Two Single-file Ni-Ti Rotary Systems in Performing Root Canal Treatment in Primary Teeth: A Randomized Clinical Trial. Int J Clin Pediatr Dent 2026;19(8):987-993.

Для цитирования: Lakshmidevi Lomada, Ahalya Penmetsa, Ravigna Peddi, Ramesh Manumanthu V, Himavarsha Mannam, Sivaram Sangadala. Evaluation of Clinical Efficiency of Two Single-file Ni-Ti Rotary Systems in Performing Root Canal Treatment in Primary Teeth: A Randomized Clinical Trial.. International journal of clinical pediatric dentistry. 2026. DOI: 10.5005/jp-journals-10005-3604.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.