MedElevator Войти в исследования
← Поиск публикаций

DOI 10.13703/j.0255-2930.20260311-k0003

Медицинская библиотека · Zhongguo zhen jiu = Chinese acupuncture & moxibustion · 2026

[Research on manipulation acquisition and operational standardization assessment of dynamic moxibustion based on computer vision technology].

Miao Xuanlei, Chen Yanjun, Wang Suizhuo, Xie Dingyi, Chen Yue, Chen Rixin

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To develop an approach to in vivo acquisition and quantitative analysis of moxa-stick trajectories in dynamic moxibustion manipulation using computer vision technology, and validate its standardization in clinical practice.

METHODS

Using color-matching target detection and a sequence-matching-oriented machine learning algorithm, the three-dimensional trajectory coordinate sequence data were converted into actual displacement and velocity in real space,and were used to evaluate the standardization of manipulation trajectory. Thirty operators were divided into 3 groups based on their years of moxibustion experience, i.e., a high seniority group, a low seniority group, and an internship group, with 10 operators in each one. In each group, the operators collected data from both the 10-minute meridian-based round-trip moxibustion trajectory and the sparrow-pecking moxibustion trajectory. The moxibustion trajectory operated by the heat-sensitive moxibustion robot served as the standard reference. The differences in the dispersion of data across 4 dimensions (length, height, width, and rate) of moxibustion were analyzed among groups, and the scores of manipulation trajectory standardization were compared.

RESULTS

The computer vision technology was capable of detecting the trajectory of dynamic moxibustion techniques and recording their three-dimensional trajectories along with velocity parameters. In comparison with the heat-sensitive moxibustion robot, the high seniority group, the low seniority group and the internship group all demonstrated the increases in all trajectory parameters and velocity dispersion and the decreases in the standardization scores (P<0.01). Among the manual manipulation groups, as clinical proficiency decreased, the trajectory parameters and velocity dispersion of meridian-along round-trip moxibustion and sparrow-pecking moxibustion were elevated(P<0.01) and the standardization scores were reduced (P<0.01).

CONCLUSION

The color-matching target detection and sequence-matching-oriented machine learning algorithm can objectively capture and record the trajectory of dynamic moxibustion, and it is suitable for the objective evaluation of the standardization of dynamic moxibustion techniques.

Для цитирования: Miao Xuanlei, Chen Yanjun, Wang Suizhuo, Xie Dingyi, Chen Yue, Chen Rixin. [Research on manipulation acquisition and operational standardization assessment of dynamic moxibustion based on computer vision technology].. Zhongguo zhen jiu = Chinese acupuncture & moxibustion. 2026. DOI: 10.13703/j.0255-2930.20260311-k0003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.